MPN: PX400
NSN : 5950-00-061-8255
CAGE Code : 27777
Manufacturer: L3 Communications Corp
Item Name : Transformer Power
Limitless Purchasing is your sourcing solution for all of your NSN part needs like PX400, offering rapid lead-times and competitive pricing on everything that we carry. Manufactured by L3 Communications Corp, this Transformer Power component is listed alongside the NSN part number PX400 for your ease of procurement. With current availability for this NSN part on our website, we invite you to begin the purchasing process by filling out the RFQ form as provided below. Once received by our team members, a dedicated account manager will review and respond in 15 minutes or less with a personalized quote that accommodates your individual needs and requirements.
NSN parts are those that follow the National Stock Number system as dictated by the United Nations, allowing for easier identification, supply, and procurement of standardized materials. As a leading distributor of NSN parts, we can help customers source the new, used, and obsolete components that they need from top global NSN parts manufacturers such as L3 Communications Corp. If you are facing an Aircraft on Ground (AOG) situation, we also offer same-day and expedited shipping for a number of items that we carry. With over 2 billion items at your disposal, Limitless Purchasing can serve as your strategic sourcing partner for all of your operational needs. Get started on the purchasing process for NSN 5950000618255 and other parts such as PX400 that you have been searching for today and see what we can do for you!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-061-8255 Item Description: Transformer Power | 5950 | 000618255 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Px400 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.750 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.380 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 4 STANDOFF, SOLDER LUG |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote