MPN: DHH0054
NSN : 5950-00-402-9025
CAGE Code : 16236
Manufacturer: Dla Land And Maritime
Item Name : Transformer Power
Limitless Purchasing is your sourcing solution for all of your NSN part needs like DHH0054, offering rapid lead-times and competitive pricing on everything that we carry. Manufactured by Dla Land And Maritime, this Transformer Power component is listed alongside the NSN part number DHH0054 for your ease of procurement. With current availability for this NSN part on our website, we invite you to begin the purchasing process by filling out the RFQ form as provided below. Once received by our team members, a dedicated account manager will review and respond in 15 minutes or less with a personalized quote that accommodates your individual needs and requirements.
NSN parts are those that follow the National Stock Number system as dictated by the United Nations, allowing for easier identification, supply, and procurement of standardized materials. As a leading distributor of NSN parts, we can help customers source the new, used, and obsolete components that they need from top global NSN parts manufacturers such as Dla Land And Maritime. If you are facing an Aircraft on Ground (AOG) situation, we also offer same-day and expedited shipping for a number of items that we carry. With over 2 billion items at your disposal, Limitless Purchasing can serve as your strategic sourcing partner for all of your operational needs. Get started on the purchasing process for NSN 5950004029025 and other parts such as DHH0054 that you have been searching for today and see what we can do for you!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-402-9025 Item Description: Transformer Power | 5950 | 004029025 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Dhh0054 | 6 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 6.062 INCHES NOMINAL6.062 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT63.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.312 INCHES NOMINAL4.312 INCHES NOMINAL |
ADAT | BODY WIDTH | 3.688 INCHES NOMINAL3.688 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP0.190 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 0.2 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1700.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY325.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY105.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NO |
CWJS | WINDING OPERATING VOLTAGE | 1700.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY1700.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY325.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY1700.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 1PRIMARY WINDING; 5SECONDARY WINDINGS |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 14 TAB, SOLDER LUG |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote