MPN: 5160-603
Alternate P/N: 5160603
NSN : 5950-00-655-0875
CAGE Code : 21856
Manufacturer: Centroid Inc
Item Name : Transformer Audio F
Limitless Purchasing is your sourcing solution for all of your NSN part needs like 5160-603, offering rapid lead-times and competitive pricing on everything that we carry. Manufactured by Centroid Inc, this Transformer Audio F component is listed alongside the NSN part number 5160-603 for your ease of procurement. With current availability for this NSN part on our website, we invite you to begin the purchasing process by filling out the RFQ form as provided below. Once received by our team members, a dedicated account manager will review and respond in 15 minutes or less with a personalized quote that accommodates your individual needs and requirements.
NSN parts are those that follow the National Stock Number system as dictated by the United Nations, allowing for easier identification, supply, and procurement of standardized materials. As a leading distributor of NSN parts, we can help customers source the new, used, and obsolete components that they need from top global NSN parts manufacturers such as Centroid Inc. If you are facing an Aircraft on Ground (AOG) situation, we also offer same-day and expedited shipping for a number of items that we carry. With over 2 billion items at your disposal, Limitless Purchasing can serve as your strategic sourcing partner for all of your operational needs. Get started on the purchasing process for NSN 5950006550875 and other parts such as 5160-603 that you have been searching for today and see what we can do for you!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-655-0875 Item Description: Transformer Audio F | 5950 | 006550875 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5160-603 | 6 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.141 INCHES NOMINAL SINGLE GROUP |
ACYW | IMPEDANCE RATING IN OHMS | 15000.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
ACYW | IMPEDANCE RATING IN OHMS | 200.0 NOMINAL SINGLE COMPONENT 1ST SECONDARY |
ACYW | IMPEDANCE RATING IN OHMS | 600.0 NOMINAL SINGLE COMPONENT 2ND SECONDARY |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 20.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 23.0 DECIBELS SINGLE COMPONENT |
ACZH | PRIMARY TO SECONDARY TURN RATIO | 1 TO 5 TO 5 SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.625 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.625 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.312 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 8.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 8 STANDOFF, SOLDER LUG |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.